UPA-CTL Anchor consists of a fold plate with a vertical hole and three horizontal holes for anti-rolling concrete panels. Moreover, it contains two steel triangles so as to increase its capacity.
This model makes possible to execute the union with the panels by expansion anchor.
Moreover, according to the exposure degree, the UPA-TL Anchors can be supplied with a zinc plated, galvanized or in stainless steel.
ESSENTIAL CHARACTERISTICS
- Dimensional and geometrical tolerances: According to EN-1090 – 2
- Weldability: Degree JR according to EN 10025-2
- Fracture toughness: 27 J a 20º C, according to EN 1993-1-10
- Fire resistance: Classified material: Class A1
- Cadmium emission: NO EMISSIONS
- Radioactivity emission: NO EMISSIONS
- Durability: Surface preparation type P3: Electroplated zinc coating EN ISO 2081
STRUCTURAL CHARACTERISTICS
- Material S275JR according to EN 10025-2
- Sizing: According to EN 1993-1
- Execution class: EXC2, according to EN 1090-2
- Fire resistance: PND
- Fatigue strength: PND (Static loads)
- Manufacture: According to EN 1090-2, execution method EXC2
- Load-bearing capacity: Characteristic values of the actions.